Solar System Losses Calculator
Calculate total system derate factor by accounting for all loss sources.
Industry Standard Derate Factors
| System Type | Typical Derate | Range |
|---|---|---|
| Residential Rooftop | 0.80-0.85 | 0.75-0.88 |
| Commercial Rooftop | 0.82-0.86 | 0.78-0.90 |
| Ground Mount Utility | 0.83-0.87 | 0.80-0.90 |
| Tracking System | 0.84-0.88 | 0.82-0.92 |
PVWatts Default Values
NREL PVWatts uses these default losses:
- Soiling: 2%
- Shading: 3%
- Snow: 0%
- Mismatch: 2%
- Wiring: 2%
- Connections: 0.5%
- Light-induced degradation: 1.5%
- Nameplate rating: 1%
- Age: 0%
- Availability: 3%
Total: ~14% losses (0.86 derate)
Optimizing System Performance
- Regular panel cleaning reduces soiling losses
- Proper string sizing minimizes mismatch
- Adequate wire sizing reduces voltage drop
- Module-level optimization (MLPE) reduces shading impact
- Quality inverters have 97-99% peak efficiency